Building-Integrated Shading

Beyond Sun Block: Innovative shading solutions not only provide protection but further architectural expression.
[ Page 2 of 2 ]  previous page Page 1 Page 2
Architectural Record
By Katherine Logan
This test is no longer available for credit

Where the Jackman project leverages a shading requirement to bring identity and gravitas to what was previously a motley cluster of volumes, the six-story, 497,000-square-foot Paulson School of Engineering and Applied Science (SEAS), a teaching and research complex under construction at Harvard University’s Allston campus, uses a shade structure to dissolve a single large building’s apparent mass. “The challenge of the SEAS was its sheer size,” says Matt Noblett, a partner at Behnisch. “We were looking for ways to disguise typical visual clues to scale, and shading helped us achieve that.”

Building on the firm’s recent work with fixed-shade wraps on the AGORA Cancer Research Center in Lausanne, Switzerland, and the Adidas headquarters expansion in Herzogenaurach, Germany—and bearing in mind what Noblett characterizes as the U.S. market’s “skittish” response to operable shading devices—the architect focused on developing a system of fixed elements. The goal was to achieve the effective coverage of an active system, but without the maintenance associated with moving parts.

After breaking the program into three smaller (but still big) volumes, and perching them on a glassy base, the design team deployed a textured shade veil to prevent windows from telegraphing the upper volumes’ scale while maintaining occupants’ quality of daylight and views. The veil consists of a lattice of stainless-steel brackets shaped to optimize sun protection for each orientation. The modular brackets, 2½ feet square, affix to a laddered framework, which in turn fastens to the steel mullions of the curtain wall. Behind the lattice, a weather envelope of glass comprises clear and opaque units. The latter, which account for every third panel and include insulation, strengthen the building’s thermal performance; staggered from floor to floor, they also contribute to the facade’s pattern.

On south-facing elevations, cowl-shaped brackets block overhead summer sun and provide ancillary side protection against morning and afternoon sun angles. On east- and west-facing elevations, L-shaped shades protect against low sun angles. And on the nominal north (actually northwest), a slender, C-shaped visor provides protection on summer afternoons. In addition to these orientation-specific types, three or four variations within each facade add complexity to the texture.

To mitigate potential glare from a high contrast between the shades’ undersides and a bright sky, the shades are perforated to create a zone of intermediate brightness. This dissolving of the bracket edges also reiterates at the aperture scale the idea of dematerialization that gave rise to the veil in the first place.

The 48,000 shades are fabricated in Germany using hydroforming technology, a process common in automobile manufacture but rare in architecture. For each of the 14 unique shade shapes, a 3-foot-3-inch-square stainless-steel block is milled with a CNC (computer numerically controlled) machine to create a negative. A 1/16-inch thick sheet of steel is placed between the negative and a top mold, with water injected to press the sheet precisely into the form. A five-axis laser then trims the excess and perforates the edges. Advantages of the technology include the brackets’ fluid forms, their geometric precision, and their light weight—with consequent cost savings in the support structure compared to welded options.

The effectiveness of the SEAS’s shade veil enables the project to rely on low-energy environmental controls, including passive ventilation, chilled beams, and radiant slabs, with more intensive cooling, dehumidification, and ventilation in areas, such as labs, where these are specifically required.

The ability to rely on low-energy environmental controls is even more crucial for Georgia Tech’s Kendeda Building for Innovative Sustainable Design, which is targeting Living Building Challenge (LBC) certification. In order to attain this status, the two-story, hybrid mass-timber structure, scheduled for completion in 2019, will have to satisfy a number of stringent requirements. One of the more difficult will be keeping occupants comfortable in Atlanta’s heat and humidity while using no more electricity than the project itself can generate.

“In a perfect world, an east–west orientation would help control heat gain, harvest daylight, and create a high-performance building,” says Joshua Gassman, sustainable-design director at Lord Aeck Sargent. But other siting factors, such as connecting to campus open space and circulation paths, took priority. “We ended up with a design strategy where the building is oriented the ‘wrong’ way,” says Gassman, “with a large west-facing facade.”

To maintain occupant comfort within the capacity of Kendeda’s super-low-energy systems, the design team began with the notion of comfort itself, using the on-line Thermal Comfort Tool from the Center for the Built Environment at the University of California, Berkeley, to play with variables, and Georgia Tech’s environmental testing chamber to understand the role of humidity. Working with the parameters from these investigations, the team performed extensive modeling to optimize the window-to-wall ratio, the glazing specifications, and shading to keep cooling loads within the energy that the building’s photovoltaic (PV) array could supply.

Kendeda’s big shading move draws on the architects’ studies of regional and international vernacular examples for hot, humid climates. Reinterpreting the traditional front porch, which creates both shade and a connective social space, the 455,000-kWh-per-year rooftop PV grid is shifted west to create a 5,900-square-foot west overhang. This porch completely solves the west shading for the second story (with additional overhang helping the south), expands the water-collection surface to meet the LBC’s net-positive water requirement, and creates sheltered teaching and gathering spaces adjacent to the building.

IMAGES: COURTESY LORD AECK SARGENT, THE MILLER HULL PARTNERSHIP, AND PAE ENGINEERS (BOTTOM); LORD AECK SARGENT AND THE MILLER HULL PARTNERSHIP (TOP)

PHOTOVOLTAIC PARASOL
A rooftop PV array will shade Kendeda’s second story. Motorized exterior blinds will protect the first floor until trees grow in (bottom). The PVs will also help shade the south facade (top).

On the ground floor, however, the porch leaves some of the west facade exposed to summer insolation. (Not to be confused with insulation, insolation is the amount of solar radiation reaching a given area in a given unit of time.) In the long term, a row of trees will provide seasonal shade and contribute to the vitality of the gathering spaces. For the shorter term, until the new trees fill out, the design team evaluated options for fixed exterior shading around the porch, but issues such as head clearance, lack of visual openness, loss of daylight, and increased wind loads made these options less than ideal for the circumstance. Instead, the west facade—and the east, where there’s no room for overhead shade—will use motorized and automated exterior blinds of clear anodized aluminum.

The clients did not immediately warm to the active-shade proposal. In fact, “they were adamantly against it,” says Gassman. But the energy analysis, combined with reassurance from the building manager at the LBC-certified Bullitt Center, which Miller Hull designed in Seattle, and which now has several years’ trouble-free experience with active shading, convinced them in the end.

Gassman describes the quest to integrate the Kendeda Building’s conservation strategies into a balanced whole—shading among them—as a four-dimensional puzzle, with the element of time as the fourth dimension. He quotes naturalist and conservationist John Muir: “When we try to pick out anything by itself, we find it hitched to everything else.” For this project, as for the SEAS and the Jackman Building, a holistic approach to shade design—hitching it to multiple priorities—generated vigorous, multifaceted solutions that are integral to their projects’ architecture.

Katharine Logan is a designer and writer focusing on architecture, sustainability, and well-being.


 

[ Page 2 of 2 ]  previous page Page 1 Page 2
Originally published in Architectural Record
Originally published in May 2018