Passive House
The three following projects are achieving Passive House standards in a variety of ways. NoVo, as a retrofit, faced unique challenges. Tapping the expertise of consultants that included Zero Energy Design, ADS Engineers, and the Levy Partnership, architects Ryall Porter Sheridan (now Ryall Sheridan) designed the headquarters to comply with the EnerPHit Passive House Institute standard, which recognizes the obstacles encountered in upgrading existing buildings. The maximums for heating- and cooling-energy consumption and air infiltration are set higher for such projects than for new Passive House construction.
One challenging aspect of the project was the deteriorated condition of the existing exterior walls. The team was forced to strip them to the cast-in-place concrete structure, including removal of the face brick and decorative facade elements. While the west elevation that opens to a narrow courtyard was refaced with an exterior insulation and finish system (EIFS), using expanded polystyrene insulation (and now painted with a spectacular mural by Katie Yamasaki), the street-facing side was more challenging. An all-new brick facade with decorative elements reproduced in cast stone was designed, but because of its proximity to the property line, most of the insulation had to be applied to the inside of the concrete envelope. Beams intersecting with exterior walls were coated with a nanogel product that controls condensation, since the beams could not be cut to accommodate a thermal break.
A thick layer of cellulose (a renewable paper-based insulation) was blown into a cavity framed inboard of the concrete walls and sheathed with an air barrier that allows migration of moisture out of the wall. A special metal batten holds the air barrier and finishes to the studs without the use of fasteners that would penetrate the membrane. Outlets and other penetrations were minimized so that each could be protected by a box impervious to the passage of air. The building has a target energy use intensity, or EUI (a measure of BTUs consumed per square foot per year) of 24.1. By contrast, the EUI of New York’s existing building stock exceeds 200.
The main floor is devoted to several meeting rooms that can be united as needed, while the fourth floor, which opens to a roof terrace, accommodates receptions. (Semi-private offices are on the floors between.) Because the assembly spaces sometimes will be occupied by large numbers of people, the rooftop ERV and a cooling tower that feeds heat pumps must manage widely varying loads, yet these loads are much less than in a conventional building because exterior temperature swings barely impinge. Occupants appreciate the acoustical isolation, too, which banishes the shouts of children outside an adjacent school and the sirens of a nearby fire station.
Neither the contractor nor subcontractors had previously built to Passive House standards. Although the workers received training, at first they struggled to meet the exacting requirements. The taping of membrane edges and intersections to achieve absolute airtightness “is not high skill,” says Ted Sheridan, a Ryall Sheridan partner. “It just requires conscientiousness.” Passive House certification is pending.
On a vastly different scale is Sendero Verde, a three-building 752,000-square-foot complex rising in East Harlem that aspires to be a model of low-energy housing. Its tallest structure is Sendero “A,” a 37-story, 348-apartment tower that is expected to be the largest multifamily Passive House building in the world when complete in 2022. The design, by Handel Architects, with Steven Winter Associates as the Passive House consultant, incorporates a rich menu of educational, recreational, and social-services spaces.
The challenges of Passive House were multiplied by the variety of exterior wall types deployed by the developers (Jonathan Rose Companies and L+M Development Partners) for each of the complex’s three buildings. The two shorter structures use different combinations of EIFS, concrete block, and metal studs. The tallest building, meanwhile, is clad in brick over a metal stud backup. The assembly’s external mineral wool insulation passes outside the edges of the floor slab to avoid a thermal bridge. Additional mineral wool is used in an interior stud wall with both insulation layers coordinated to ensure a continuous thermal and air barrier at the window frame. The wall assembly has thermal resistance of R-20, about double a well-performing conventional wall.
The interior side of the tower’s wall assembly includes a “service cavity” so that conduit and electrical outlets are accommodated inboard of the insulation and vapor barrier. Otherwise, each wall penetration would have to be painstakingly wrapped to prevent air infiltration. Mechanically, the building combines heat-recovery ventilation with VRF condensers linked to air-handling units in each apartment. The project is designed to an EUI of 38.1, compared with the current New York multifamily median of 130.
IMAGES: COURTESY GENERATE ARCHITECTURE + TECHNOLOGIES/PLACETAILOR
Boston-area firms Placetailor and Generate are combining Passive House strategies with the carbon-storage capacity of mass timber to create a 14-unit apartment building (top) for the city’s Roxbury neighborhood. The building will include co-working space on the ground floor (bottom).
Marrying the emerging technology of cross-laminated timber (CLT) with the Passive House standard will multiply the climate benefits of 201 Hamden, a 14-unit, five-story apartment building and co-working space slated to start construction this summer in Boston’s Roxbury neighborhood. Developed by the local design-build firm Placetailor, the project deploys Passive House tactics to reduce operating energy and emissions, while the wood stores carbon, avoiding the significant embodied emissions that would have been generated by steel or concrete construction.
The project’s CLT expertise comes from Generate, an architecture firm created at MIT with team members from Harvard, and support from a Wood Innovation grant. The group developed a system with timber panels forming the floors, walls, and roof, providing structural strength through the continuous attachment of the panel edges, so that they work like a line of extra-hefty plywood boxes fastened together. From a building-code standpoint, the system is akin to heavy timber framing long used in construction. The structure will be fully sprinklered, and also protected by char that would form on the panels’ outer layer, preserving their structural integrity in the event of a fire.
The construction system is well suited to Passive House because of the low heat conductivity across the wood exterior panels, compared to masonry or light-gauge metal or wood stud-wall assemblies. Inboard of the metal rainscreen cladding, insulation is installed on both sides of the CLT panels.
The strategy is also expected to speed construction. Through BIM, the design will be translated into instructions to shop-cut the CLT members, explains John Klein, the CEO of Generate. Modular bathrooms will also be fabricated off-site. “There is a higher first cost but incredibly fast building erection,” he says. The surface of the CLT panels is appealing, so some wall and ceiling surfaces will be exposed in the finished units. But the interiors will also include drywall-and-stud cavities, allowing the concealment of electrical conduit, plumbing, and other services. The project’s angled roofs are designed to accommodate solar panels, which will help it achieve carbon neutrality.
Some skeptics have wondered if Passive House would work in America. But as the inventiveness and ambitions of projects like 201 Hampden, Sendero Verde, and NoVo demonstrate, the standard is taking hold in a variety of structures. “It is dominating the conversation around low-energy buildings,” says Yetsuh Frank, the managing director of strategy and programs at the Building Energy Exchange, a New York nonprofit. It has developed a track record of operational savings, says Frank, while other methods too often fail to meet promised performance. He sees Passive House envelope requirements migrating into building codes in such cities as New York, Seattle, and Vancouver.
The growing number of Passive House projects has spurred the development of materials and equipment that make compliance easier. Architects designing to the standard point, by way of example, to products from triple-glazed windows to mini-split mechanical systems, once exotic in the U.S. and now readily available.
Clearly, Passive House is an outlier no more.
Supplemental Materials
“Passive NYC: A snapshot of low-energy building opportunities, barriers, and resources” Building Energy Exchange, Executive Summary and Overview (through page 10).
James S. Russell, FAIA, a journalist who often focuses on sustainability and resilience, is the author of The Agile City: Building Well Being and Wealth in an Era of Climate Change (Island Press, 2011).
Architectural Record is the #1 source for design news, architect continuing education, and info on sustainability, houses, projects, and architectural products. |